How the cost is worked out
An air conditioner's efficiency rating tells you how many Btu of cooling it delivers for each watt-hour of electricity. Central systems are rated in SEER2 and window units in CEER, but both are Btu per watt-hour, so the arithmetic is the same: divide the cooling capacity by the rating to get the average power the unit draws while it runs.
Cost per day = capacity in Btu/h ÷ rating ÷ 1,000 × hours running × price per kWh
Example at the U.S. average price. A 3-ton central air conditioner (36,000 Btu/h) rated SEER2 13.4 draws about 2,687 W while it runs. Eight hours of running uses 21.5 kWh. At 18.16¢ per kWh that is $3.90 a day, about $118.72 a month and $359.08 over a 92-day summer.
The same cooling from a SEER2 17.0 unit would cost $283.04 for the summer, $76.04 less.
What SEER2 and CEER mean
SEER2 is the seasonal energy efficiency ratio under the test procedure that took effect on January 1, 2023. It averages a central system's efficiency over a range of outdoor temperatures, so it suits a cost estimate for a whole summer. On the hottest afternoons a unit works less efficiently than its SEER2 suggests, which is why the federal rules also set a separate rating (EER2) at 95°F.
Window units use CEER, the combined energy efficiency ratio, which also counts the small amount of power a unit uses while plugged in but switched off. A higher number means less electricity for the same cooling: going from SEER2 13.4 to 17.0 cuts the electricity for the same cooling by 21%.
The lowest efficiency allowed where you live
Since January 1, 2023, a new split-system central air conditioner under 45,000 Btu/h must be rated at least SEER2 13.4. In the Southeast and Southwest the minimum is SEER2 14.3. That covers Alabama, Arizona, Arkansas, California, Delaware, District of Columbia, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, Nevada, New Mexico, North Carolina, Oklahoma, South Carolina, Tennessee, Texas and Virginia. The calculator fills in your state's minimum when you choose it, which is a fair starting point for a system installed since then. Older systems are often less efficient.
For window units, models made before May 26, 2026 in the most common size (8,000 to 13,900 Btu/h, with louvered sides) had to reach a CEER of 10.9. Models made from that date must reach 16.0. At the U.S. average price, an 8,000 Btu/h unit running 8 hours a day costs about $32.43 a month at the old minimum and $22.09 at the new one.
Ways to cut the cost
The U.S. Department of Energy says you can save as much as 10% a year on heating and cooling by setting the thermostat back 7 to 10°F for 8 hours a day. In summer that means letting the house get warmer while you are out or asleep. A warmer house gains heat from outside more slowly, so the AC has less to remove.
Setting the thermostat colder than normal does not cool the house any faster. It only makes the system run longer once it gets there. The thermostat setback calculator works out what a setback is worth on your bill.
What this estimate leaves out
- Run time is the biggest unknown. It depends on the weather, the size of the unit, insulation and the thermostat setting. A smart thermostat or a home energy monitor will show your real hours.
- The indoor blower fan is included in SEER2 ratings for central systems, but a fan left running on its own after cooling stops is not.
- Heat pumps cool exactly like central air conditioners, so the result applies to them in summer. Their winter cost is covered by the heat pump vs furnace calculator.
- Your electricity price may change with the time of day or the season. Type the rate from your bill for an exact answer.
Questions
How many watts does a central air conditioner use?
Divide the capacity by the SEER2 rating. A 3-ton (36,000 Btu/h) unit at SEER2 13.4 averages about 2,687 W while running. It draws more on very hot afternoons and less in mild weather.
Is it cheaper to leave the AC on all day or turn it up when I leave?
Turning it up saves energy. The Department of Energy explains that a warmer house gains heat from outside more slowly, so the system has less heat to remove overall, even after it cools the house down again in the evening.
Does setting the thermostat lower cool the house faster?
No. An air conditioner cools at the same rate whatever the setting. A lower setting only makes it run longer and overcool the house.
Is a window unit cheaper to run than central air?
Per hour, a window unit uses far less because it cools one room. At the U.S. average price an 8,000 Btu/h unit at CEER 10.9 costs about $1.07 for 8 hours, against $3.90 for a 3-ton central system. If you only need one room cool, the window unit wins. Cooling a whole house with several window units is usually less efficient.
What SEER2 should I buy?
The minimum allowed for a new central unit is SEER2 13.4, or 14.3 in the Southeast and Southwest. A higher rating costs more up front and saves on every summer bill. Put a few ratings into the comparison field to see what each is worth per summer at your price, then compare that with the difference in price between the units.
Sources
- Electricity prices: U.S. Energy Information Administration, Electric Power Monthly, Table 5.6.A, August 2026 (2026 values are preliminary).
- Minimum efficiency for central and window air conditioners, and the Southeast and Southwest state lists: Code of Federal Regulations, 10 CFR 430.32, energy conservation standards for room and central air conditioners (eCFR, up to date as of November 13, 2026).
- Thermostat setback savings and advice: U.S. Department of Energy, Thermostats, Energy Saver (archived copy; the page is no longer on energy.gov).
Prices last updated November 17, 2026 from EIA data. Reviewed by the Kilowatt Almanac editor. Found a mistake? Tell us and we will fix it.